Hi to everyone:

 

Everytime i run a php command from the console i get this error message:

 

root@visum /opt/observium# php discovery.php -u

MIB search path: /opt/observium/mibs

Cannot find module (SNMPv2-MIB): At line 1 in (none)

Cannot find module (IF-MIB): At line 1 in (none)

Cannot find module (IP-MIB): At line 1 in (none)

Cannot find module (TCP-MIB): At line 1 in (none)

Cannot find module (UDP-MIB): At line 1 in (none)

Cannot find module (HOST-RESOURCES-MIB): At line 1 in (none)

Cannot find module (NOTIFICATION-LOG-MIB): At line 1 in (none)

Cannot find module (DISMAN-EVENT-MIB): At line 1 in (none)

Cannot find module (DISMAN-SCHEDULE-MIB): At line 1 in (none)

Cannot find module (HOST-RESOURCES-TYPES): At line 1 in (none)

Cannot find module (MTA-MIB): At line 1 in (none)

Cannot find module (NETWORK-SERVICES-MIB): At line 1 in (none)

Cannot find module (UCD-DISKIO-MIB): At line 1 in (none)

Cannot find module (UCD-DLMOD-MIB): At line 1 in (none)

Cannot find module (LM-SENSORS-MIB): At line 1 in (none)

Cannot find module (UCD-SNMP-MIB): At line 1 in (none)

Cannot find module (UCD-DEMO-MIB): At line 1 in (none)

Cannot find module (SNMP-TARGET-MIB): At line 1 in (none)

Cannot find module (NET-SNMP-AGENT-MIB): At line 1 in (none)

Cannot find module (SNMP-MPD-MIB): At line 1 in (none)

Cannot find module (SNMP-USER-BASED-SM-MIB): At line 1 in (none)

Cannot find module (SNMP-FRAMEWORK-MIB): At line 1 in (none)

Cannot find module (SNMP-VIEW-BASED-ACM-MIB): At line 1 in (none)

Cannot find module (SNMP-COMMUNITY-MIB): At line 1 in (none)

Cannot find module (IPV6-ICMP-MIB): At line 1 in (none)

Cannot find module (IPV6-MIB): At line 1 in (none)

Cannot find module (IPV6-TCP-MIB): At line 1 in (none)

Cannot find module (IPV6-UDP-MIB): At line 1 in (none)

Cannot find module (IP-FORWARD-MIB): At line 1 in (none)

Cannot find module (NET-SNMP-PASS-MIB): At line 1 in (none)

Cannot find module (NET-SNMP-EXTEND-MIB): At line 1 in (none)

Cannot find module (SNMP-NOTIFICATION-MIB): At line 1 in (none)

Cannot find module (SNMPv2-TM): At line 1 in (none)

Cannot find module (NET-SNMP-VACM-MIB): At line 1 in (none)

__________________

 

please advice

Forum: 
Tags: 
Jeremy Davis's picture

I was able to reporoduce this straight away, so thanks so much for reporting.

It actually took me ages to work out what the issue was. But it seems that there are a few MIBs pre-compiled into the snmp software. But our default config only uses the Observium provided MIBs. The conf file (/etc/snmp/snmp.conf) we ship be default looks like this:

mibdirs /opt/observium/mibs

The fix is to add the Observium provided MIBs to the default, rather than replace them. To do that, the conf file needs a '+' at the start of the path to add. I.e.:

mibdirs +/opt/observium/mibs

You can manually edit the conf file, or just run the sed command below (run as root):

sed -i "s|mibdirs /opt/observium/mibs|mibdirs +/opt/observium/mibs|" /etc/snmp/snmp.conf

After that:

root@observium /opt/observium# ./discovery.php -u

  ___   _                              _
 / _ \ | |__   ___   ___  _ __ __   __(_) _   _  _ __ ___
| | | || '_ \ / __| / _ \| '__|\ \ / /| || | | || '_ ` _ \
| |_| || |_) |\__ \|  __/| |    \ V / | || |_| || | | | | |
 \___/ |_.__/ |___/ \___||_|     \_/  |_| \__,_||_| |_| |_|
                     Observium Community Edition 19.8.10000
                                   http://www.observium.org

-- Database is up to date.

I've opened an issue and I'll apply the fix to the build code and rebuild soonish.

Please post back and confirm that my fix works for you too.

Luis Olavarrieta's picture

is working!!! thanks!!!

Jeremy Davis's picture

Awesome! :)

Marco Caggianese's picture

Hi Jeremy, I just tried the fix you suggested. My outcome is different. Here's the output:
root@observium /opt/observium# ./discovery.php -u
MIB search path: /root/.snmp/mibs:/usr/share/snmp/mibs:/usr/share/snmp/mibs/iana:/usr/share/snmp/mibs/ietf:/usr/share/mibs/site:/usr/share/snmp/mibs:/usr/share/mibs/iana:/usr/share/mibs/ietf:/usr/share/mibs/netsnmp:/opt/observium/mibs
Cannot find module (SNMPv2-MIB): At line 1 in (none)
Cannot find module (IF-MIB): At line 1 in (none)
Cannot find module (IP-MIB): At line 1 in (none)
Cannot find module (TCP-MIB): At line 1 in (none)
Cannot find module (UDP-MIB): At line 1 in (none)
Cannot find module (HOST-RESOURCES-MIB): At line 1 in (none)
Cannot find module (NOTIFICATION-LOG-MIB): At line 1 in (none)
Cannot find module (DISMAN-EVENT-MIB): At line 1 in (none)
Cannot find module (DISMAN-SCHEDULE-MIB): At line 1 in (none)
Cannot find module (HOST-RESOURCES-TYPES): At line 1 in (none)
Cannot find module (MTA-MIB): At line 1 in (none)
Cannot find module (NETWORK-SERVICES-MIB): At line 1 in (none)
Cannot find module (SNMPv2-TC): At line 15 in /usr/share/snmp/mibs/UCD-DISKIO-MIB.txt
Cannot find module (SNMPv2-SMI): At line 34 in /usr/share/snmp/mibs/UCD-SNMP-MIB.txt
Cannot find module (SNMPv2-TC): At line 37 in /usr/share/snmp/mibs/UCD-SNMP-MIB.txt
Did not find 'enterprises' in module #-1 (/usr/share/snmp/mibs/UCD-SNMP-MIB.txt)
Did not find 'DisplayString' in module #-1 (/usr/share/snmp/mibs/UCD-SNMP-MIB.txt)
Did not find 'TruthValue' in module #-1 (/usr/share/snmp/mibs/UCD-SNMP-MIB.txt)
Unlinked OID in UCD-SNMP-MIB: ucdavis ::= { enterprises 2021 }
Undefined identifier: enterprises near line 39 of /usr/share/snmp/mibs/UCD-SNMP-MIB.txt
Did not find 'DisplayString' in module #-1 (/usr/share/snmp/mibs/UCD-DISKIO-MIB.txt)
Did not find 'ucdExperimental' in module UCD-SNMP-MIB (/usr/share/snmp/mibs/UCD-DISKIO-MIB.txt)
Unlinked OID in UCD-DISKIO-MIB: ucdDiskIOMIB ::= { ucdExperimental 15 }
Undefined identifier: ucdExperimental near line 19 of /usr/share/snmp/mibs/UCD-DISKIO-MIB.txt
Cannot find module (SNMPv2-TC): At line 10 in /usr/share/snmp/mibs/UCD-DLMOD-MIB.txt
Did not find 'DisplayString' in module #-1 (/usr/share/snmp/mibs/UCD-DLMOD-MIB.txt)
Did not find 'ucdExperimental' in module UCD-SNMP-MIB (/usr/share/snmp/mibs/UCD-DLMOD-MIB.txt)
Unlinked OID in UCD-DLMOD-MIB: ucdDlmodMIB ::= { ucdExperimental 14 }
Undefined identifier: ucdExperimental near line 13 of /usr/share/snmp/mibs/UCD-DLMOD-MIB.txt
Cannot find module (SNMPv2-TC): At line 15 in /usr/share/snmp/mibs/LM-SENSORS-MIB.txt
Did not find 'DisplayString' in module #-1 (/usr/share/snmp/mibs/LM-SENSORS-MIB.txt)
Did not find 'ucdExperimental' in module UCD-SNMP-MIB (/usr/share/snmp/mibs/LM-SENSORS-MIB.txt)
Unlinked OID in LM-SENSORS-MIB: lmSensors ::= { ucdExperimental 16 }
Undefined identifier: ucdExperimental near line 32 of /usr/share/snmp/mibs/LM-SENSORS-MIB.txt
Did not find 'ucdavis' in module UCD-SNMP-MIB (/usr/share/snmp/mibs/UCD-DEMO-MIB.txt)
Unlinked OID in UCD-DEMO-MIB: ucdDemoMIB ::= { ucdavis 14 }
Undefined identifier: ucdavis near line 7 of /usr/share/snmp/mibs/UCD-DEMO-MIB.txt
Cannot find module (SNMP-TARGET-MIB): At line 1 in (none)
Cannot find module (SNMP-FRAMEWORK-MIB): At line 9 in /usr/share/snmp/mibs/NET-SNMP-AGENT-MIB.txt
Cannot find module (SNMPv2-SMI): At line 8 in /usr/share/snmp/mibs/NET-SNMP-MIB.txt
Did not find 'enterprises' in module #-1 (/usr/share/snmp/mibs/NET-SNMP-MIB.txt)
Unlinked OID in NET-SNMP-MIB: netSnmp ::= { enterprises 8072 }
Undefined identifier: enterprises near line 10 of /usr/share/snmp/mibs/NET-SNMP-MIB.txt
Cannot find module (SNMPv2-TC): At line 21 in /usr/share/snmp/mibs/NET-SNMP-AGENT-MIB.txt
Did not find 'SnmpAdminString' in module #-1 (/usr/share/snmp/mibs/NET-SNMP-AGENT-MIB.txt)
Did not find 'netSnmpObjects' in module NET-SNMP-MIB (/usr/share/snmp/mibs/NET-SNMP-AGENT-MIB.txt)
Did not find 'netSnmpModuleIDs' in module NET-SNMP-MIB (/usr/share/snmp/mibs/NET-SNMP-AGENT-MIB.txt)
Did not find 'netSnmpNotifications' in module NET-SNMP-MIB (/usr/share/snmp/mibs/NET-SNMP-AGENT-MIB.txt)
Did not find 'netSnmpGroups' in module NET-SNMP-MIB (/usr/share/snmp/mibs/NET-SNMP-AGENT-MIB.txt)
Did not find 'DisplayString' in module #-1 (/usr/share/snmp/mibs/NET-SNMP-AGENT-MIB.txt)
Did not find 'RowStatus' in module #-1 (/usr/share/snmp/mibs/NET-SNMP-AGENT-MIB.txt)
Did not find 'TruthValue' in module #-1 (/usr/share/snmp/mibs/NET-SNMP-AGENT-MIB.txt)
Unlinked OID in NET-SNMP-AGENT-MIB: nsAgentNotifyGroup ::= { netSnmpGroups 9 }
Undefined identifier: netSnmpGroups near line 545 of /usr/share/snmp/mibs/NET-SNMP-AGENT-MIB.txt
Unlinked OID in NET-SNMP-AGENT-MIB: nsTransactionGroup ::= { netSnmpGroups 8 }
Undefined identifier: netSnmpGroups near line 536 of /usr/share/snmp/mibs/NET-SNMP-AGENT-MIB.txt
Unlinked OID in NET-SNMP-AGENT-MIB: nsConfigGroups ::= { netSnmpGroups 7 }
Undefined identifier: netSnmpGroups near line 515 of /usr/share/snmp/mibs/NET-SNMP-AGENT-MIB.txt
Unlinked OID in NET-SNMP-AGENT-MIB: nsCacheGroup ::= { netSnmpGroups 4 }
Undefined identifier: netSnmpGroups near line 505 of /usr/share/snmp/mibs/NET-SNMP-AGENT-MIB.txt
Unlinked OID in NET-SNMP-AGENT-MIB: nsModuleGroup ::= { netSnmpGroups 2 }
Undefined identifier: netSnmpGroups near line 495 of /usr/share/snmp/mibs/NET-SNMP-AGENT-MIB.txt
Unlinked OID in NET-SNMP-AGENT-MIB: netSnmpAgentMIB ::= { netSnmpModuleIDs 2 }
Undefined identifier: netSnmpModuleIDs near line 24 of /usr/share/snmp/mibs/NET-SNMP-AGENT-MIB.txt
Unlinked OID in NET-SNMP-AGENT-MIB: nsTransactions ::= { netSnmpObjects 8 }
Undefined identifier: netSnmpObjects near line 55 of /usr/share/snmp/mibs/NET-SNMP-AGENT-MIB.txt
Unlinked OID in NET-SNMP-AGENT-MIB: nsConfiguration ::= { netSnmpObjects 7 }
Undefined identifier: netSnmpObjects near line 54 of /usr/share/snmp/mibs/NET-SNMP-AGENT-MIB.txt
Unlinked OID in NET-SNMP-AGENT-MIB: nsErrorHistory ::= { netSnmpObjects 6 }
Undefined identifier: netSnmpObjects near line 53 of /usr/share/snmp/mibs/NET-SNMP-AGENT-MIB.txt
Unlinked OID in NET-SNMP-AGENT-MIB: nsCache ::= { netSnmpObjects 5 }
Undefined identifier: netSnmpObjects near line 52 of /usr/share/snmp/mibs/NET-SNMP-AGENT-MIB.txt
Unlinked OID in NET-SNMP-AGENT-MIB: nsDLMod ::= { netSnmpObjects 4 }
Undefined identifier: netSnmpObjects near line 51 of /usr/share/snmp/mibs/NET-SNMP-AGENT-MIB.txt
Unlinked OID in NET-SNMP-AGENT-MIB: nsExtensions ::= { netSnmpObjects 3 }
Undefined identifier: netSnmpObjects near line 50 of /usr/share/snmp/mibs/NET-SNMP-AGENT-MIB.txt
Unlinked OID in NET-SNMP-AGENT-MIB: nsMibRegistry ::= { netSnmpObjects 2 }
Undefined identifier: netSnmpObjects near line 49 of /usr/share/snmp/mibs/NET-SNMP-AGENT-MIB.txt
Unlinked OID in NET-SNMP-AGENT-MIB: nsVersion ::= { netSnmpObjects 1 }
Undefined identifier: netSnmpObjects near line 48 of /usr/share/snmp/mibs/NET-SNMP-AGENT-MIB.txt
Unlinked OID in NET-SNMP-AGENT-MIB: nsNotifyRestart ::= { netSnmpNotifications 3 }
Undefined identifier: netSnmpNotifications near line 482 of /usr/share/snmp/mibs/NET-SNMP-AGENT-MIB.txt
Unlinked OID in NET-SNMP-AGENT-MIB: nsNotifyShutdown ::= { netSnmpNotifications 2 }
Undefined identifier: netSnmpNotifications near line 476 of /usr/share/snmp/mibs/NET-SNMP-AGENT-MIB.txt
Unlinked OID in NET-SNMP-AGENT-MIB: nsNotifyStart ::= { netSnmpNotifications 1 }
Undefined identifier: netSnmpNotifications near line 470 of /usr/share/snmp/mibs/NET-SNMP-AGENT-MIB.txt
Cannot find module (SNMP-MPD-MIB): At line 1 in (none)
Cannot find module (SNMP-USER-BASED-SM-MIB): At line 1 in (none)
Cannot find module (SNMP-FRAMEWORK-MIB): At line 1 in (none)
Cannot find module (SNMP-VIEW-BASED-ACM-MIB): At line 1 in (none)
Cannot find module (SNMP-COMMUNITY-MIB): At line 1 in (none)
Cannot find module (IPV6-ICMP-MIB): At line 1 in (none)
Cannot find module (IPV6-MIB): At line 1 in (none)
Cannot find module (IPV6-TCP-MIB): At line 1 in (none)
Cannot find module (IPV6-UDP-MIB): At line 1 in (none)
Cannot find module (IP-FORWARD-MIB): At line 1 in (none)
Cannot find module (SNMP-FRAMEWORK-MIB): At line 10 in /usr/share/snmp/mibs/NET-SNMP-PASS-MIB.txt
Cannot find module (SNMP-FRAMEWORK-MIB): At line 10 in /usr/share/snmp/mibs/NET-SNMP-EXAMPLES-MIB.txt
Cannot find module (SNMPv2-TC): At line 12 in /usr/share/snmp/mibs/NET-SNMP-EXAMPLES-MIB.txt
Cannot find module (INET-ADDRESS-MIB): At line 13 in /usr/share/snmp/mibs/NET-SNMP-EXAMPLES-MIB.txt
Did not find 'SnmpAdminString' in module #-1 (/usr/share/snmp/mibs/NET-SNMP-EXAMPLES-MIB.txt)
Did not find 'netSnmp' in module NET-SNMP-MIB (/usr/share/snmp/mibs/NET-SNMP-EXAMPLES-MIB.txt)
Did not find 'RowStatus' in module #-1 (/usr/share/snmp/mibs/NET-SNMP-EXAMPLES-MIB.txt)
Did not find 'StorageType' in module #-1 (/usr/share/snmp/mibs/NET-SNMP-EXAMPLES-MIB.txt)
Did not find 'InetAddressType' in module #-1 (/usr/share/snmp/mibs/NET-SNMP-EXAMPLES-MIB.txt)
Did not find 'InetAddress' in module #-1 (/usr/share/snmp/mibs/NET-SNMP-EXAMPLES-MIB.txt)
Unlinked OID in NET-SNMP-EXAMPLES-MIB: netSnmpExamples ::= { netSnmp 2 }
Undefined identifier: netSnmp near line 16 of /usr/share/snmp/mibs/NET-SNMP-EXAMPLES-MIB.txt
Did not find 'SnmpAdminString' in module #-1 (/usr/share/snmp/mibs/NET-SNMP-PASS-MIB.txt)
Did not find 'netSnmpExamples' in module NET-SNMP-EXAMPLES-MIB (/usr/share/snmp/mibs/NET-SNMP-PASS-MIB.txt)
Unlinked OID in NET-SNMP-PASS-MIB: netSnmpPassExamples ::= { netSnmpExamples 255 }
Undefined identifier: netSnmpExamples near line 14 of /usr/share/snmp/mibs/NET-SNMP-PASS-MIB.txt
Cannot find module (SNMPv2-TC): At line 16 in /usr/share/snmp/mibs/NET-SNMP-EXTEND-MIB.txt
Did not find 'nsExtensions' in module NET-SNMP-AGENT-MIB (/usr/share/snmp/mibs/NET-SNMP-EXTEND-MIB.txt)
Did not find 'DisplayString' in module #-1 (/usr/share/snmp/mibs/NET-SNMP-EXTEND-MIB.txt)
Did not find 'RowStatus' in module #-1 (/usr/share/snmp/mibs/NET-SNMP-EXTEND-MIB.txt)
Did not find 'StorageType' in module #-1 (/usr/share/snmp/mibs/NET-SNMP-EXTEND-MIB.txt)
Unlinked OID in NET-SNMP-EXTEND-MIB: nsExtendGroups ::= { nsExtensions 3 }
Undefined identifier: nsExtensions near line 39 of /usr/share/snmp/mibs/NET-SNMP-EXTEND-MIB.txt
Unlinked OID in NET-SNMP-EXTEND-MIB: nsExtendObjects ::= { nsExtensions 2 }
Undefined identifier: nsExtensions near line 38 of /usr/share/snmp/mibs/NET-SNMP-EXTEND-MIB.txt
Unlinked OID in NET-SNMP-EXTEND-MIB: netSnmpExtendMIB ::= { nsExtensions 1 }
Undefined identifier: nsExtensions near line 19 of /usr/share/snmp/mibs/NET-SNMP-EXTEND-MIB.txt
Cannot find module (SNMP-NOTIFICATION-MIB): At line 1 in (none)
Cannot find module (SNMPv2-TM): At line 1 in (none)
Cannot find module (SNMP-FRAMEWORK-MIB): At line 9 in /usr/share/snmp/mibs/NET-SNMP-VACM-MIB.txt
Cannot find module (SNMP-VIEW-BASED-ACM-MIB): At line 16 in /usr/share/snmp/mibs/NET-SNMP-VACM-MIB.txt
Cannot find module (SNMPv2-TC): At line 25 in /usr/share/snmp/mibs/NET-SNMP-VACM-MIB.txt
Did not find 'SnmpAdminString' in module #-1 (/usr/share/snmp/mibs/NET-SNMP-VACM-MIB.txt)
Did not find 'netSnmpObjects' in module NET-SNMP-MIB (/usr/share/snmp/mibs/NET-SNMP-VACM-MIB.txt)
Did not find 'netSnmpGroups' in module NET-SNMP-MIB (/usr/share/snmp/mibs/NET-SNMP-VACM-MIB.txt)
Did not find 'vacmGroupName' in module #-1 (/usr/share/snmp/mibs/NET-SNMP-VACM-MIB.txt)
Did not find 'vacmAccessContextPrefix' in module #-1 (/usr/share/snmp/mibs/NET-SNMP-VACM-MIB.txt)
Did not find 'vacmAccessSecurityModel' in module #-1 (/usr/share/snmp/mibs/NET-SNMP-VACM-MIB.txt)
Did not find 'vacmAccessSecurityLevel' in module #-1 (/usr/share/snmp/mibs/NET-SNMP-VACM-MIB.txt)
Did not find 'DisplayString' in module #-1 (/usr/share/snmp/mibs/NET-SNMP-VACM-MIB.txt)
Did not find 'RowStatus' in module #-1 (/usr/share/snmp/mibs/NET-SNMP-VACM-MIB.txt)
Did not find 'StorageType' in module #-1 (/usr/share/snmp/mibs/NET-SNMP-VACM-MIB.txt)
Unlinked OID in NET-SNMP-VACM-MIB: netSnmpVacmMIB ::= { netSnmpObjects 9 }
Undefined identifier: netSnmpObjects near line 28 of /usr/share/snmp/mibs/NET-SNMP-VACM-MIB.txt
Cannot adopt OID in UCD-SNMP-MIB: logMatchRegExCompilation ::= { logMatchEntry 101 }
Cannot adopt OID in UCD-SNMP-MIB: logMatchErrorFlag ::= { logMatchEntry 100 }
Cannot adopt OID in UCD-SNMP-MIB: logMatchCycle ::= { logMatchEntry 11 }
Cannot adopt OID in UCD-SNMP-MIB: logMatchCount ::= { logMatchEntry 10 }
Cannot adopt OID in UCD-SNMP-MIB: logMatchCounter ::= { logMatchEntry 9 }
Cannot adopt OID in UCD-SNMP-MIB: logMatchCurrentCount ::= { logMatchEntry 8 }
Cannot adopt OID in UCD-SNMP-MIB: logMatchCurrentCounter ::= { logMatchEntry 7 }
Cannot adopt OID in UCD-SNMP-MIB: logMatchGlobalCount ::= { logMatchEntry 6 }
Cannot adopt OID in UCD-SNMP-MIB: logMatchGlobalCounter ::= { logMatchEntry 5 }
Cannot adopt OID in UCD-SNMP-MIB: logMatchRegEx ::= { logMatchEntry 4 }
Cannot adopt OID in UCD-SNMP-MIB: logMatchFilename ::= { logMatchEntry 3 }
Cannot adopt OID in UCD-SNMP-MIB: logMatchName ::= { logMatchEntry 2 }
Cannot adopt OID in UCD-SNMP-MIB: logMatchIndex ::= { logMatchEntry 1 }
Cannot adopt OID in NET-SNMP-VACM-MIB: nsVacmAccessEntry ::= { nsVacmAccessTable 1 }
Cannot adopt OID in UCD-SNMP-MIB: extErrFixCmd ::= { extEntry 103 }
Cannot adopt OID in UCD-SNMP-MIB: extErrFix ::= { extEntry 102 }
Cannot adopt OID in UCD-SNMP-MIB: extOutput ::= { extEntry 101 }
Cannot adopt OID in UCD-SNMP-MIB: extResult ::= { extEntry 100 }
Cannot adopt OID in UCD-SNMP-MIB: extCommand ::= { extEntry 3 }
Cannot adopt OID in UCD-SNMP-MIB: extNames ::= { extEntry 2 }
Cannot adopt OID in UCD-SNMP-MIB: extIndex ::= { extEntry 1 }
Cannot adopt OID in UCD-DEMO-MIB: ucdDemoPublic ::= { ucdDemoMIBObjects 1 }
Cannot adopt OID in UCD-DLMOD-MIB: dlmodTable ::= { ucdDlmodMIB 2 }
Cannot adopt OID in UCD-DLMOD-MIB: dlmodNextIndex ::= { ucdDlmodMIB 1 }
Cannot adopt OID in NET-SNMP-EXAMPLES-MIB: netSnmpExamples ::= { netSnmp 2 }
Cannot adopt OID in NET-SNMP-MIB: netSnmpConformance ::= { netSnmp 5 }
Cannot adopt OID in NET-SNMP-MIB: netSnmpNotificationPrefix ::= { netSnmp 4 }
Cannot adopt OID in NET-SNMP-MIB: netSnmpExperimental ::= { netSnmp 9999 }
Cannot adopt OID in NET-SNMP-MIB: netSnmpEnumerations ::= { netSnmp 3 }
Cannot adopt OID in NET-SNMP-MIB: netSnmpObjects ::= { netSnmp 1 }
Cannot adopt OID in UCD-SNMP-MIB: versionDoDebugging ::= { version 20 }
Cannot adopt OID in UCD-SNMP-MIB: versionSavePersistentData ::= { version 13 }
Cannot adopt OID in UCD-SNMP-MIB: versionRestartAgent ::= { version 12 }
Cannot adopt OID in UCD-SNMP-MIB: versionUpdateConfig ::= { version 11 }
Cannot adopt OID in UCD-SNMP-MIB: versionClearCache ::= { version 10 }
Cannot adopt OID in UCD-SNMP-MIB: versionConfigureOptions ::= { version 6 }
Cannot adopt OID in UCD-SNMP-MIB: versionIdent ::= { version 5 }
Cannot adopt OID in UCD-SNMP-MIB: versionCDate ::= { version 4 }
Cannot adopt OID in UCD-SNMP-MIB: versionDate ::= { version 3 }
Cannot adopt OID in UCD-SNMP-MIB: versionTag ::= { version 2 }
Cannot adopt OID in UCD-SNMP-MIB: versionIndex ::= { version 1 }
Cannot adopt OID in NET-SNMP-EXAMPLES-MIB: netSnmpExampleHeartbeatNotification ::= { netSnmpExampleNotificationPrefix 1 }
Cannot adopt OID in NET-SNMP-AGENT-MIB: nsCacheStatus ::= { nsCacheEntry 3 }
Cannot adopt OID in NET-SNMP-AGENT-MIB: nsCacheTimeout ::= { nsCacheEntry 2 }
Cannot adopt OID in NET-SNMP-AGENT-MIB: nsCachedOID ::= { nsCacheEntry 1 }
Cannot adopt OID in UCD-SNMP-MIB: unknown ::= { ucdSnmpAgent 255 }
Cannot adopt OID in UCD-SNMP-MIB: dragonfly ::= { ucdSnmpAgent 17 }
Cannot adopt OID in UCD-SNMP-MIB: macosx ::= { ucdSnmpAgent 16 }
Cannot adopt OID in UCD-SNMP-MIB: aix ::= { ucdSnmpAgent 15 }
Cannot adopt OID in UCD-SNMP-MIB: hpux11 ::= { ucdSnmpAgent 14 }
Cannot adopt OID in UCD-SNMP-MIB: win32 ::= { ucdSnmpAgent 13 }
Cannot adopt OID in UCD-SNMP-MIB: openbsd ::= { ucdSnmpAgent 12 }
Cannot adopt OID in UCD-SNMP-MIB: bsdi ::= { ucdSnmpAgent 11 }
Cannot adopt OID in UCD-SNMP-MIB: linux ::= { ucdSnmpAgent 10 }
Cannot adopt OID in UCD-SNMP-MIB: irix ::= { ucdSnmpAgent 9 }
Cannot adopt OID in UCD-SNMP-MIB: freebsd ::= { ucdSnmpAgent 8 }
Cannot adopt OID in UCD-SNMP-MIB: netbsd1 ::= { ucdSnmpAgent 7 }
Cannot adopt OID in UCD-SNMP-MIB: hpux10 ::= { ucdSnmpAgent 6 }
Cannot adopt OID in UCD-SNMP-MIB: ultrix ::= { ucdSnmpAgent 5 }
Cannot adopt OID in UCD-SNMP-MIB: osf ::= { ucdSnmpAgent 4 }
Cannot adopt OID in UCD-SNMP-MIB: solaris ::= { ucdSnmpAgent 3 }
Cannot adopt OID in UCD-SNMP-MIB: sunos4 ::= { ucdSnmpAgent 2 }
Cannot adopt OID in UCD-SNMP-MIB: hpux9 ::= { ucdSnmpAgent 1 }
Cannot adopt OID in NET-SNMP-EXTEND-MIB: nsExtendOutputGroup ::= { nsExtendGroups 2 }
Cannot adopt OID in NET-SNMP-EXTEND-MIB: nsExtendConfigGroup ::= { nsExtendGroups 1 }
Cannot adopt OID in UCD-DISKIO-MIB: diskIOEntry ::= { diskIOTable 1 }
Cannot adopt OID in NET-SNMP-AGENT-MIB: nsTransactionEntry ::= { nsTransactionTable 1 }
Cannot adopt OID in NET-SNMP-MIB: netSnmpGroups ::= { netSnmpConformance 2 }
Cannot adopt OID in NET-SNMP-MIB: netSnmpCompliances ::= { netSnmpConformance 1 }
Cannot adopt OID in UCD-SNMP-MIB: mrModuleName ::= { mrEntry 2 }
Cannot adopt OID in UCD-SNMP-MIB: mrIndex ::= { mrEntry 1 }
Cannot adopt OID in NET-SNMP-AGENT-MIB: nsDebugTokenEntry ::= { nsDebugTokenTable 1 }
Cannot adopt OID in NET-SNMP-EXTEND-MIB: nsExtendStatus ::= { nsExtendConfigEntry 21 }
Cannot adopt OID in NET-SNMP-EXTEND-MIB: nsExtendStorage ::= { nsExtendConfigEntry 20 }
Cannot adopt OID in NET-SNMP-EXTEND-MIB: nsExtendRunType ::= { nsExtendConfigEntry 7 }
Cannot adopt OID in NET-SNMP-EXTEND-MIB: nsExtendExecType ::= { nsExtendConfigEntry 6 }
Cannot adopt OID in NET-SNMP-EXTEND-MIB: nsExtendCacheTime ::= { nsExtendConfigEntry 5 }
Cannot adopt OID in NET-SNMP-EXTEND-MIB: nsExtendInput ::= { nsExtendConfigEntry 4 }
Cannot adopt OID in NET-SNMP-EXTEND-MIB: nsExtendArgs ::= { nsExtendConfigEntry 3 }
Cannot adopt OID in NET-SNMP-EXTEND-MIB: nsExtendCommand ::= { nsExtendConfigEntry 2 }
Cannot adopt OID in NET-SNMP-EXTEND-MIB: nsExtendToken ::= { nsExtendConfigEntry 1 }
Cannot adopt OID in NET-SNMP-AGENT-MIB: nsModuleTable ::= { nsMibRegistry 1 }
Cannot adopt OID in NET-SNMP-MIB: netSnmpPlaypen ::= { netSnmpExperimental 9999 }
Cannot adopt OID in NET-SNMP-EXAMPLES-MIB: netSnmpIETFWGEntry ::= { netSnmpIETFWGTable 1 }
Cannot adopt OID in UCD-SNMP-MIB: prErrFixCmd ::= { prEntry 103 }
Cannot adopt OID in UCD-SNMP-MIB: prErrFix ::= { prEntry 102 }
Cannot adopt OID in UCD-SNMP-MIB: prErrMessage ::= { prEntry 101 }
Cannot adopt OID in UCD-SNMP-MIB: prErrorFlag ::= { prEntry 100 }
Cannot adopt OID in UCD-SNMP-MIB: prCount ::= { prEntry 5 }
Cannot adopt OID in UCD-SNMP-MIB: prMax ::= { prEntry 4 }
Cannot adopt OID in UCD-SNMP-MIB: prMin ::= { prEntry 3 }
Cannot adopt OID in UCD-SNMP-MIB: prNames ::= { prEntry 2 }
Cannot adopt OID in UCD-SNMP-MIB: prIndex ::= { prEntry 1 }
Cannot adopt OID in UCD-DLMOD-MIB: dlmodEntry ::= { dlmodTable 1 }
Cannot adopt OID in UCD-SNMP-MIB: memSwapErrorMsg ::= { memory 101 }
Cannot adopt OID in UCD-SNMP-MIB: memSwapError ::= { memory 100 }
Cannot adopt OID in UCD-SNMP-MIB: memUsedRealTXT ::= { memory 17 }
Cannot adopt OID in UCD-SNMP-MIB: memUsedSwapTXT ::= { memory 16 }
Cannot adopt OID in UCD-SNMP-MIB: memCached ::= { memory 15 }
Cannot adopt OID in UCD-SNMP-MIB: memBuffer ::= { memory 14 }
Cannot adopt OID in UCD-SNMP-MIB: memShared ::= { memory 13 }
Cannot adopt OID in UCD-SNMP-MIB: memMinimumSwap ::= { memory 12 }
Cannot adopt OID in UCD-SNMP-MIB: memTotalFree ::= { memory 11 }
Cannot adopt OID in UCD-SNMP-MIB: memAvailRealTXT ::= { memory 10 }
Cannot adopt OID in UCD-SNMP-MIB: memTotalRealTXT ::= { memory 9 }
Cannot adopt OID in UCD-SNMP-MIB: memAvailSwapTXT ::= { memory 8 }
Cannot adopt OID in UCD-SNMP-MIB: memTotalSwapTXT ::= { memory 7 }
Cannot adopt OID in UCD-SNMP-MIB: memAvailReal ::= { memory 6 }
Cannot adopt OID in UCD-SNMP-MIB: memTotalReal ::= { memory 5 }
Cannot adopt OID in UCD-SNMP-MIB: memAvailSwap ::= { memory 4 }
Cannot adopt OID in UCD-SNMP-MIB: memTotalSwap ::= { memory 3 }
Cannot adopt OID in UCD-SNMP-MIB: memErrorName ::= { memory 2 }
Cannot adopt OID in UCD-SNMP-MIB: memIndex ::= { memory 1 }
Cannot adopt OID in UCD-DEMO-MIB: ucdDemoMIBObjects ::= { ucdDemoMIB 1 }
Cannot adopt OID in NET-SNMP-AGENT-MIB: nsModuleTimeout ::= { nsModuleEntry 6 }
Cannot adopt OID in NET-SNMP-AGENT-MIB: nsModuleModes ::= { nsModuleEntry 5 }
Cannot adopt OID in NET-SNMP-AGENT-MIB: nsModuleName ::= { nsModuleEntry 4 }
Cannot adopt OID in NET-SNMP-AGENT-MIB: nsmRegistrationPriority ::= { nsModuleEntry 3 }
Cannot adopt OID in NET-SNMP-AGENT-MIB: nsmRegistrationPoint ::= { nsModuleEntry 2 }
Cannot adopt OID in NET-SNMP-AGENT-MIB: nsmContextName ::= { nsModuleEntry 1 }
Cannot adopt OID in LM-SENSORS-MIB: lmMiscSensorsEntry ::= { lmMiscSensorsTable 1 }
Cannot adopt OID in NET-SNMP-MIB: netSnmpNotificationObjects ::= { netSnmpNotificationPrefix 1 }
Cannot adopt OID in NET-SNMP-MIB: netSnmpNotifications ::= { netSnmpNotificationPrefix 0 }
Cannot adopt OID in NET-SNMP-PASS-MIB: netSnmpPassTable ::= { netSnmpPassExamples 2 }
Cannot adopt OID in NET-SNMP-PASS-MIB: netSnmpPassOIDValue ::= { netSnmpPassExamples 99 }
Cannot adopt OID in NET-SNMP-PASS-MIB: netSnmpPassGauge ::= { netSnmpPassExamples 6 }
Cannot adopt OID in NET-SNMP-PASS-MIB: netSnmpPassCounter ::= { netSnmpPassExamples 5 }
Cannot adopt OID in NET-SNMP-PASS-MIB: netSnmpPassIpAddress ::= { netSnmpPassExamples 4 }
Cannot adopt OID in NET-SNMP-PASS-MIB: netSnmpPassTimeTicks ::= { netSnmpPassExamples 3 }
Cannot adopt OID in NET-SNMP-PASS-MIB: netSnmpPassString ::= { netSnmpPassExamples 1 }
Cannot adopt OID in NET-SNMP-MIB: netSnmpDomains ::= { netSnmpEnumerations 3 }
Cannot adopt OID in NET-SNMP-MIB: netSnmpAgentOIDs ::= { netSnmpEnumerations 2 }
Cannot adopt OID in NET-SNMP-MIB: netSnmpModuleIDs ::= { netSnmpEnumerations 1 }
Cannot adopt OID in LM-SENSORS-MIB: lmFanSensorsEntry ::= { lmFanSensorsTable 1 }
Cannot adopt OID in LM-SENSORS-MIB: lmTempSensorsEntry ::= { lmTempSensorsTable 1 }
Cannot adopt OID in NET-SNMP-AGENT-MIB: nsModuleGroup ::= { netSnmpGroups 2 }
Cannot adopt OID in NET-SNMP-AGENT-MIB: nsCacheGroup ::= { netSnmpGroups 4 }
Cannot adopt OID in NET-SNMP-AGENT-MIB: nsConfigGroups ::= { netSnmpGroups 7 }
Cannot adopt OID in NET-SNMP-AGENT-MIB: nsTransactionGroup ::= { netSnmpGroups 8 }
Cannot adopt OID in NET-SNMP-AGENT-MIB: nsAgentNotifyGroup ::= { netSnmpGroups 9 }
Cannot adopt OID in UCD-SNMP-MIB: fileEntry ::= { fileTable 1 }
Cannot adopt OID in NET-SNMP-VACM-MIB: nsVacmStatus ::= { nsVacmAccessEntry 5 }
Cannot adopt OID in NET-SNMP-VACM-MIB: nsVacmStorageType ::= { nsVacmAccessEntry 4 }
Cannot adopt OID in NET-SNMP-VACM-MIB: nsVacmViewName ::= { nsVacmAccessEntry 3 }
Cannot adopt OID in NET-SNMP-VACM-MIB: nsVacmContextMatch ::= { nsVacmAccessEntry 2 }
Cannot adopt OID in NET-SNMP-VACM-MIB: nsVacmAuthType ::= { nsVacmAccessEntry 1 }
Cannot adopt OID in NET-SNMP-EXTEND-MIB: netSnmpExtendMIB ::= { nsExtensions 1 }
Cannot adopt OID in NET-SNMP-EXTEND-MIB: nsExtendObjects ::= { nsExtensions 2 }
Cannot adopt OID in NET-SNMP-EXTEND-MIB: nsExtendGroups ::= { nsExtensions 3 }
Cannot adopt OID in LM-SENSORS-MIB: lmVoltSensorsEntry ::= { lmVoltSensorsTable 1 }
Cannot adopt OID in NET-SNMP-MIB: netSnmp ::= { enterprises 8072 }
Cannot adopt OID in UCD-SNMP-MIB: ucdavis ::= { enterprises 2021 }
Cannot adopt OID in UCD-DISKIO-MIB: diskIONWrittenX ::= { diskIOEntry 13 }
Cannot adopt OID in UCD-DISKIO-MIB: diskIONReadX ::= { diskIOEntry 12 }
Cannot adopt OID in UCD-DISKIO-MIB: diskIOLA15 ::= { diskIOEntry 11 }
Cannot adopt OID in UCD-DISKIO-MIB: diskIOLA5 ::= { diskIOEntry 10 }
Cannot adopt OID in UCD-DISKIO-MIB: diskIOLA1 ::= { diskIOEntry 9 }
Cannot adopt OID in UCD-DISKIO-MIB: diskIOWrites ::= { diskIOEntry 6 }
Cannot adopt OID in UCD-DISKIO-MIB: diskIOReads ::= { diskIOEntry 5 }
Cannot adopt OID in UCD-DISKIO-MIB: diskIONWritten ::= { diskIOEntry 4 }
Cannot adopt OID in UCD-DISKIO-MIB: diskIONRead ::= { diskIOEntry 3 }
Cannot adopt OID in UCD-DISKIO-MIB: diskIODevice ::= { diskIOEntry 2 }
Cannot adopt OID in UCD-DISKIO-MIB: diskIOIndex ::= { diskIOEntry 1 }
Cannot adopt OID in NET-SNMP-AGENT-MIB: nsTransactionMode ::= { nsTransactionEntry 2 }
Cannot adopt OID in NET-SNMP-AGENT-MIB: nsTransactionID ::= { nsTransactionEntry 1 }
Cannot adopt OID in NET-SNMP-AGENT-MIB: nsDebugTokenStatus ::= { nsDebugTokenEntry 4 }
Cannot adopt OID in NET-SNMP-AGENT-MIB: nsDebugTokenPrefix ::= { nsDebugTokenEntry 2 }
Cannot adopt OID in NET-SNMP-EXAMPLES-MIB: nsIETFWGChair2 ::= { netSnmpIETFWGEntry 3 }
Cannot adopt OID in NET-SNMP-EXAMPLES-MIB: nsIETFWGChair1 ::= { netSnmpIETFWGEntry 2 }
Cannot adopt OID in NET-SNMP-EXAMPLES-MIB: nsIETFWGName ::= { netSnmpIETFWGEntry 1 }
Cannot adopt OID in NET-SNMP-AGENT-MIB: nsLoggingTable ::= { nsConfigLogging 1 }
Cannot adopt OID in NET-SNMP-EXAMPLES-MIB: netSnmpHostsEntry ::= { netSnmpHostsTable 1 }
Cannot adopt OID in UCD-DLMOD-MIB: dlmodStatus ::= { dlmodEntry 5 }
Cannot adopt OID in UCD-DLMOD-MIB: dlmodError ::= { dlmodEntry 4 }
Cannot adopt OID in UCD-DLMOD-MIB: dlmodPath ::= { dlmodEntry 3 }
Cannot adopt OID in UCD-DLMOD-MIB: dlmodName ::= { dlmodEntry 2 }
Cannot adopt OID in UCD-DLMOD-MIB: dlmodIndex ::= { dlmodEntry 1 }
Cannot adopt OID in LM-SENSORS-MIB: lmMiscSensorsValue ::= { lmMiscSensorsEntry 3 }
Cannot adopt OID in LM-SENSORS-MIB: lmMiscSensorsDevice ::= { lmMiscSensorsEntry 2 }
Cannot adopt OID in LM-SENSORS-MIB: lmMiscSensorsIndex ::= { lmMiscSensorsEntry 1 }
Cannot adopt OID in NET-SNMP-PASS-MIB: netSnmpPassEntry ::= { netSnmpPassTable 1 }
Cannot adopt OID in LM-SENSORS-MIB: lmSensors ::= { ucdExperimental 16 }
Cannot adopt OID in UCD-DLMOD-MIB: ucdDlmodMIB ::= { ucdExperimental 14 }
Cannot adopt OID in UCD-DISKIO-MIB: ucdDiskIOMIB ::= { ucdExperimental 15 }
Cannot adopt OID in UCD-SNMP-MIB: dskEntry ::= { dskTable 1 }
Cannot adopt OID in NET-SNMP-AGENT-MIB: netSnmpAgentMIB ::= { netSnmpModuleIDs 2 }
Cannot adopt OID in LM-SENSORS-MIB: lmFanSensorsValue ::= { lmFanSensorsEntry 3 }
Cannot adopt OID in LM-SENSORS-MIB: lmFanSensorsDevice ::= { lmFanSensorsEntry 2 }
Cannot adopt OID in LM-SENSORS-MIB: lmFanSensorsIndex ::= { lmFanSensorsEntry 1 }
Cannot adopt OID in LM-SENSORS-MIB: lmTempSensorsValue ::= { lmTempSensorsEntry 3 }
Cannot adopt OID in LM-SENSORS-MIB: lmTempSensorsDevice ::= { lmTempSensorsEntry 2 }
Cannot adopt OID in LM-SENSORS-MIB: lmTempSensorsIndex ::= { lmTempSensorsEntry 1 }
Cannot adopt OID in UCD-SNMP-MIB: logMatchTable ::= { logMatch 2 }
Cannot adopt OID in UCD-SNMP-MIB: logMatchMaxEntries ::= { logMatch 1 }
Cannot adopt OID in NET-SNMP-AGENT-MIB: nsLoggingEntry ::= { nsLoggingTable 1 }
Cannot adopt OID in UCD-SNMP-MIB: fileErrorMsg ::= { fileEntry 101 }
Cannot adopt OID in UCD-SNMP-MIB: fileErrorFlag ::= { fileEntry 100 }
Cannot adopt OID in UCD-SNMP-MIB: fileMax ::= { fileEntry 4 }
Cannot adopt OID in UCD-SNMP-MIB: fileSize ::= { fileEntry 3 }
Cannot adopt OID in UCD-SNMP-MIB: fileName ::= { fileEntry 2 }
Cannot adopt OID in UCD-SNMP-MIB: fileIndex ::= { fileEntry 1 }
Cannot adopt OID in NET-SNMP-EXTEND-MIB: nsExtendOutput2Table ::= { nsExtendObjects 4 }
Cannot adopt OID in NET-SNMP-EXTEND-MIB: nsExtendOutput1Table ::= { nsExtendObjects 3 }
Cannot adopt OID in NET-SNMP-EXTEND-MIB: nsExtendConfigTable ::= { nsExtendObjects 2 }
Cannot adopt OID in NET-SNMP-EXTEND-MIB: nsExtendNumEntries ::= { nsExtendObjects 1 }
Cannot adopt OID in NET-SNMP-EXTEND-MIB: nsExtendOutput1Entry ::= { nsExtendOutput1Table 1 }
Cannot adopt OID in UCD-SNMP-MIB: ssCpuNumCpus ::= { systemStats 67 }
Cannot adopt OID in UCD-SNMP-MIB: ssCpuRawGuestNice ::= { systemStats 66 }
Cannot adopt OID in UCD-SNMP-MIB: ssCpuRawGuest ::= { systemStats 65 }
Cannot adopt OID in UCD-SNMP-MIB: ssCpuRawSteal ::= { systemStats 64 }
Cannot adopt OID in UCD-SNMP-MIB: ssRawSwapOut ::= { systemStats 63 }
Cannot adopt OID in UCD-SNMP-MIB: ssRawSwapIn ::= { systemStats 62 }
Cannot adopt OID in UCD-SNMP-MIB: ssCpuRawSoftIRQ ::= { systemStats 61 }
Cannot adopt OID in UCD-SNMP-MIB: ssRawContexts ::= { systemStats 60 }
Cannot adopt OID in UCD-SNMP-MIB: ssRawInterrupts ::= { systemStats 59 }
Cannot adopt OID in UCD-SNMP-MIB: ssIORawReceived ::= { systemStats 58 }
Cannot adopt OID in UCD-SNMP-MIB: ssIORawSent ::= { systemStats 57 }
Cannot adopt OID in UCD-SNMP-MIB: ssCpuRawInterrupt ::= { systemStats 56 }
Cannot adopt OID in UCD-SNMP-MIB: ssCpuRawKernel ::= { systemStats 55 }
Cannot adopt OID in UCD-SNMP-MIB: ssCpuRawWait ::= { systemStats 54 }
Cannot adopt OID in UCD-SNMP-MIB: ssCpuRawIdle ::= { systemStats 53 }
Cannot adopt OID in UCD-SNMP-MIB: ssCpuRawSystem ::= { systemStats 52 }
Cannot adopt OID in UCD-SNMP-MIB: ssCpuRawNice ::= { systemStats 51 }
Cannot adopt OID in UCD-SNMP-MIB: ssCpuRawUser ::= { systemStats 50 }
Cannot adopt OID in UCD-SNMP-MIB: ssCpuIdle ::= { systemStats 11 }
Cannot adopt OID in UCD-SNMP-MIB: ssCpuSystem ::= { systemStats 10 }
Cannot adopt OID in UCD-SNMP-MIB: ssCpuUser ::= { systemStats 9 }
Cannot adopt OID in UCD-SNMP-MIB: ssSysContext ::= { systemStats 8 }
Cannot adopt OID in UCD-SNMP-MIB: ssSysInterrupts ::= { systemStats 7 }
Cannot adopt OID in UCD-SNMP-MIB: ssIOReceive ::= { systemStats 6 }
Cannot adopt OID in UCD-SNMP-MIB: ssIOSent ::= { systemStats 5 }
Cannot adopt OID in UCD-SNMP-MIB: ssSwapOut ::= { systemStats 4 }
Cannot adopt OID in UCD-SNMP-MIB: ssSwapIn ::= { systemStats 3 }
Cannot adopt OID in UCD-SNMP-MIB: ssErrorName ::= { systemStats 2 }
Cannot adopt OID in UCD-SNMP-MIB: ssIndex ::= { systemStats 1 }
Cannot adopt OID in NET-SNMP-EXTEND-MIB: nsExtendOutput2Entry ::= { nsExtendOutput2Table 1 }
Cannot adopt OID in UCD-SNMP-MIB: laEntry ::= { laTable 1 }
Cannot adopt OID in NET-SNMP-AGENT-MIB: nsCacheTable ::= { nsCache 3 }
Cannot adopt OID in NET-SNMP-AGENT-MIB: nsCacheEnabled ::= { nsCache 2 }
Cannot adopt OID in NET-SNMP-AGENT-MIB: nsCacheDefaultTimeout ::= { nsCache 1 }
Cannot adopt OID in UCD-SNMP-MIB: logMatchEntry ::= { logMatchTable 1 }
Cannot adopt OID in UCD-SNMP-MIB: extEntry ::= { extTable 1 }
Cannot adopt OID in NET-SNMP-AGENT-MIB: nsConfigLogging ::= { nsConfiguration 2 }
Cannot adopt OID in NET-SNMP-AGENT-MIB: nsConfigDebug ::= { nsConfiguration 1 }
Cannot adopt OID in NET-SNMP-EXAMPLES-MIB: netSnmpExampleString ::= { netSnmpExampleScalars 3 }
Cannot adopt OID in NET-SNMP-EXAMPLES-MIB: netSnmpExampleSleeper ::= { netSnmpExampleScalars 2 }
Cannot adopt OID in NET-SNMP-EXAMPLES-MIB: netSnmpExampleInteger ::= { netSnmpExampleScalars 1 }
Cannot adopt OID in LM-SENSORS-MIB: lmVoltSensorsValue ::= { lmVoltSensorsEntry 3 }
Cannot adopt OID in LM-SENSORS-MIB: lmVoltSensorsDevice ::= { lmVoltSensorsEntry 2 }
Cannot adopt OID in LM-SENSORS-MIB: lmVoltSensorsIndex ::= { lmVoltSensorsEntry 1 }
Cannot adopt OID in NET-SNMP-AGENT-MIB: nsCacheEntry ::= { nsCacheTable 1 }
Cannot adopt OID in NET-SNMP-AGENT-MIB: nsDebugTokenTable ::= { nsConfigDebug 4 }
Cannot adopt OID in NET-SNMP-AGENT-MIB: nsDebugDumpPdu ::= { nsConfigDebug 3 }
Cannot adopt OID in NET-SNMP-AGENT-MIB: nsDebugOutputAll ::= { nsConfigDebug 2 }
Cannot adopt OID in NET-SNMP-AGENT-MIB: nsDebugEnabled ::= { nsConfigDebug 1 }
Cannot adopt OID in UCD-DEMO-MIB: ucdDemoPassphrase ::= { ucdDemoPublic 4 }
Cannot adopt OID in UCD-DEMO-MIB: ucdDemoUserList ::= { ucdDemoPublic 3 }
Cannot adopt OID in UCD-DEMO-MIB: ucdDemoPublicString ::= { ucdDemoPublic 2 }
Cannot adopt OID in UCD-DEMO-MIB: ucdDemoResetKeys ::= { ucdDemoPublic 1 }
Cannot adopt OID in NET-SNMP-EXAMPLES-MIB: netSnmpExampleHeartbeatName ::= { netSnmpExampleNotificationObjects 2 }
Cannot adopt OID in NET-SNMP-EXAMPLES-MIB: netSnmpExampleHeartbeatRate ::= { netSnmpExampleNotificationObjects 1 }
Cannot adopt OID in NET-SNMP-PASS-MIB: netSnmpPassExamples ::= { netSnmpExamples 255 }
Cannot adopt OID in NET-SNMP-EXAMPLES-MIB: netSnmpExampleNotifications ::= { netSnmpExamples 3 }
Cannot adopt OID in NET-SNMP-EXAMPLES-MIB: netSnmpExampleTables ::= { netSnmpExamples 2 }
Cannot adopt OID in NET-SNMP-EXAMPLES-MIB: netSnmpExampleScalars ::= { netSnmpExamples 1 }
Cannot adopt OID in NET-SNMP-VACM-MIB: nsVacmAccessTable ::= { netSnmpVacmMIB 1 }
Cannot adopt OID in UCD-SNMP-MIB: ucdShutdown ::= { ucdTraps 2 }
Cannot adopt OID in UCD-SNMP-MIB: ucdStart ::= { ucdTraps 1 }
Cannot adopt OID in LM-SENSORS-MIB: lmMiscSensorsTable ::= { lmSensors 5 }
Cannot adopt OID in LM-SENSORS-MIB: lmVoltSensorsTable ::= { lmSensors 4 }
Cannot adopt OID in LM-SENSORS-MIB: lmFanSensorsTable ::= { lmSensors 3 }
Cannot adopt OID in LM-SENSORS-MIB: lmTempSensorsTable ::= { lmSensors 2 }
Cannot adopt OID in LM-SENSORS-MIB: lmSensorsMIB ::= { lmSensors 1 }
Cannot adopt OID in UCD-SNMP-MIB: mrEntry ::= { mrTable 1 }
Cannot adopt OID in NET-SNMP-EXTEND-MIB: nsExtendConfigEntry ::= { nsExtendConfigTable 1 }
Cannot adopt OID in NET-SNMP-EXAMPLES-MIB: netSnmpHostRowStatus ::= { netSnmpHostsEntry 5 }
Cannot adopt OID in NET-SNMP-EXAMPLES-MIB: netSnmpHostStorage ::= { netSnmpHostsEntry 4 }
Cannot adopt OID in NET-SNMP-EXAMPLES-MIB: netSnmpHostAddress ::= { netSnmpHostsEntry 3 }
Cannot adopt OID in NET-SNMP-EXAMPLES-MIB: netSnmpHostAddressType ::= { netSnmpHostsEntry 2 }
Cannot adopt OID in NET-SNMP-EXAMPLES-MIB: netSnmpHostName ::= { netSnmpHostsEntry 1 }
Cannot adopt OID in UCD-SNMP-MIB: prEntry ::= { prTable 1 }
Cannot adopt OID in NET-SNMP-EXAMPLES-MIB: netSnmpExampleNotification ::= { netSnmpExampleNotifications 1 }
Cannot adopt OID in NET-SNMP-EXAMPLES-MIB: netSnmpExampleNotificationObjects ::= { netSnmpExampleNotifications 2 }
Cannot adopt OID in NET-SNMP-EXAMPLES-MIB: netSnmpExampleNotificationPrefix ::= { netSnmpExampleNotifications 0 }
Cannot adopt OID in NET-SNMP-EXAMPLES-MIB: netSnmpHostsTable ::= { netSnmpExampleTables 2 }
Cannot adopt OID in NET-SNMP-EXAMPLES-MIB: netSnmpIETFWGTable ::= { netSnmpExampleTables 1 }
Cannot adopt OID in NET-SNMP-PASS-MIB: netSnmpPassOID ::= { netSnmpPassEntry 3 }
Cannot adopt OID in NET-SNMP-PASS-MIB: netSnmpPassInteger ::= { netSnmpPassEntry 2 }
Cannot adopt OID in NET-SNMP-PASS-MIB: netSnmpPassIndex ::= { netSnmpPassEntry 1 }
Cannot adopt OID in NET-SNMP-VACM-MIB: netSnmpVacmMIB ::= { netSnmpObjects 9 }
Cannot adopt OID in NET-SNMP-AGENT-MIB: nsVersion ::= { netSnmpObjects 1 }
Cannot adopt OID in NET-SNMP-AGENT-MIB: nsMibRegistry ::= { netSnmpObjects 2 }
Cannot adopt OID in NET-SNMP-AGENT-MIB: nsExtensions ::= { netSnmpObjects 3 }
Cannot adopt OID in NET-SNMP-AGENT-MIB: nsDLMod ::= { netSnmpObjects 4 }
Cannot adopt OID in NET-SNMP-AGENT-MIB: nsCache ::= { netSnmpObjects 5 }
Cannot adopt OID in NET-SNMP-AGENT-MIB: nsErrorHistory ::= { netSnmpObjects 6 }
Cannot adopt OID in NET-SNMP-AGENT-MIB: nsConfiguration ::= { netSnmpObjects 7 }
Cannot adopt OID in NET-SNMP-AGENT-MIB: nsTransactions ::= { netSnmpObjects 8 }
Cannot adopt OID in UCD-DEMO-MIB: ucdDemoMIB ::= { ucdavis 14 }
Cannot adopt OID in UCD-SNMP-MIB: logMatch ::= { ucdavis 16 }
Cannot adopt OID in UCD-SNMP-MIB: fileTable ::= { ucdavis 15 }
Cannot adopt OID in UCD-SNMP-MIB: ucdTraps ::= { ucdavis 251 }
Cannot adopt OID in UCD-SNMP-MIB: systemStats ::= { ucdavis 11 }
Cannot adopt OID in UCD-SNMP-MIB: mrTable ::= { ucdavis 102 }
Cannot adopt OID in UCD-SNMP-MIB: snmperrs ::= { ucdavis 101 }
Cannot adopt OID in UCD-SNMP-MIB: version ::= { ucdavis 100 }
Cannot adopt OID in UCD-SNMP-MIB: laTable ::= { ucdavis 10 }
Cannot adopt OID in UCD-SNMP-MIB: dskTable ::= { ucdavis 9 }
Cannot adopt OID in UCD-SNMP-MIB: memory ::= { ucdavis 4 }
Cannot adopt OID in UCD-SNMP-MIB: extTable ::= { ucdavis 8 }
Cannot adopt OID in UCD-SNMP-MIB: prTable ::= { ucdavis 2 }
Cannot adopt OID in UCD-SNMP-MIB: ucdSnmpAgent ::= { ucdavis 250 }
Cannot adopt OID in UCD-SNMP-MIB: ucdExperimental ::= { ucdavis 13 }
Cannot adopt OID in UCD-SNMP-MIB: ucdInternal ::= { ucdavis 12 }
Cannot adopt OID in NET-SNMP-AGENT-MIB: nsModuleEntry ::= { nsModuleTable 1 }
Cannot adopt OID in UCD-SNMP-MIB: dskErrorMsg ::= { dskEntry 101 }
Cannot adopt OID in UCD-SNMP-MIB: dskErrorFlag ::= { dskEntry 100 }
Cannot adopt OID in UCD-SNMP-MIB: dskUsedHigh ::= { dskEntry 16 }
Cannot adopt OID in UCD-SNMP-MIB: dskUsedLow ::= { dskEntry 15 }
Cannot adopt OID in UCD-SNMP-MIB: dskAvailHigh ::= { dskEntry 14 }
Cannot adopt OID in UCD-SNMP-MIB: dskAvailLow ::= { dskEntry 13 }
Cannot adopt OID in UCD-SNMP-MIB: dskTotalHigh ::= { dskEntry 12 }
Cannot adopt OID in UCD-SNMP-MIB: dskTotalLow ::= { dskEntry 11 }
Cannot adopt OID in UCD-SNMP-MIB: dskPercentNode ::= { dskEntry 10 }
Cannot adopt OID in UCD-SNMP-MIB: dskPercent ::= { dskEntry 9 }
Cannot adopt OID in UCD-SNMP-MIB: dskUsed ::= { dskEntry 8 }
Cannot adopt OID in UCD-SNMP-MIB: dskAvail ::= { dskEntry 7 }
Cannot adopt OID in UCD-SNMP-MIB: dskTotal ::= { dskEntry 6 }
Cannot adopt OID in UCD-SNMP-MIB: dskMinPercent ::= { dskEntry 5 }
Cannot adopt OID in UCD-SNMP-MIB: dskMinimum ::= { dskEntry 4 }
Cannot adopt OID in UCD-SNMP-MIB: dskDevice ::= { dskEntry 3 }
Cannot adopt OID in UCD-SNMP-MIB: dskPath ::= { dskEntry 2 }
Cannot adopt OID in UCD-SNMP-MIB: dskIndex ::= { dskEntry 1 }
Cannot adopt OID in UCD-DISKIO-MIB: diskIOTable ::= { ucdDiskIOMIB 1 }
Cannot adopt OID in NET-SNMP-AGENT-MIB: nsLoggingGroup ::= { nsConfigGroups 2 }
Cannot adopt OID in NET-SNMP-AGENT-MIB: nsDebugGroup ::= { nsConfigGroups 1 }
Cannot adopt OID in UCD-SNMP-MIB: snmperrErrMessage ::= { snmperrs 101 }
Cannot adopt OID in UCD-SNMP-MIB: snmperrErrorFlag ::= { snmperrs 100 }
Cannot adopt OID in UCD-SNMP-MIB: snmperrNames ::= { snmperrs 2 }
Cannot adopt OID in UCD-SNMP-MIB: snmperrIndex ::= { snmperrs 1 }
Cannot adopt OID in NET-SNMP-AGENT-MIB: nsTransactionTable ::= { nsTransactions 1 }
Cannot adopt OID in NET-SNMP-AGENT-MIB: nsLogStatus ::= { nsLoggingEntry 5 }
Cannot adopt OID in NET-SNMP-AGENT-MIB: nsLogMaxLevel ::= { nsLoggingEntry 4 }
Cannot adopt OID in NET-SNMP-AGENT-MIB: nsLogType ::= { nsLoggingEntry 3 }
Cannot adopt OID in NET-SNMP-AGENT-MIB: nsLogToken ::= { nsLoggingEntry 2 }
Cannot adopt OID in NET-SNMP-AGENT-MIB: nsLogLevel ::= { nsLoggingEntry 1 }
Cannot adopt OID in NET-SNMP-EXTEND-MIB: nsExtendResult ::= { nsExtendOutput1Entry 4 }
Cannot adopt OID in NET-SNMP-EXTEND-MIB: nsExtendOutNumLines ::= { nsExtendOutput1Entry 3 }
Cannot adopt OID in NET-SNMP-EXTEND-MIB: nsExtendOutputFull ::= { nsExtendOutput1Entry 2 }
Cannot adopt OID in NET-SNMP-EXTEND-MIB: nsExtendOutput1Line ::= { nsExtendOutput1Entry 1 }
Cannot adopt OID in NET-SNMP-EXTEND-MIB: nsExtendOutLine ::= { nsExtendOutput2Entry 2 }
Cannot adopt OID in NET-SNMP-EXTEND-MIB: nsExtendLineIndex ::= { nsExtendOutput2Entry 1 }
Cannot adopt OID in NET-SNMP-AGENT-MIB: nsNotifyStart ::= { netSnmpNotifications 1 }
Cannot adopt OID in NET-SNMP-AGENT-MIB: nsNotifyShutdown ::= { netSnmpNotifications 2 }
Cannot adopt OID in NET-SNMP-AGENT-MIB: nsNotifyRestart ::= { netSnmpNotifications 3 }
Cannot adopt OID in UCD-SNMP-MIB: laErrMessage ::= { laEntry 101 }
Cannot adopt OID in UCD-SNMP-MIB: laErrorFlag ::= { laEntry 100 }
Cannot adopt OID in UCD-SNMP-MIB: laLoadFloat ::= { laEntry 6 }
Cannot adopt OID in UCD-SNMP-MIB: laLoadInt ::= { laEntry 5 }
Cannot adopt OID in UCD-SNMP-MIB: laConfig ::= { laEntry 4 }
Cannot adopt OID in UCD-SNMP-MIB: laLoad ::= { laEntry 3 }
Cannot adopt OID in UCD-SNMP-MIB: laNames ::= { laEntry 2 }
Cannot adopt OID in UCD-SNMP-MIB: laIndex ::= { laEntry 1 }

  ___   _                              _
 / _ \ | |__   ___   ___  _ __ __   __(_) _   _  _ __ ___
| | | || '_ \ / __| / _ \| '__|\ \ / /| || | | || '_ ` _ \
| |_| || |_) |\__ \|  __/| |    \ V / | || |_| || | | | | |
 \___/ |_.__/ |___/ \___||_|     \_/  |_| \__,_||_| |_| |_|
                     Observium Community Edition 19.8.10000
                                   http://www.observium.org

-- Database is up to date.
Thanks in advance for your help
Jeremy Davis's picture

Hi Marco, I edited your post before publishing (fixed the mis-spelling of my name, plus posted your output from your pastebin link).

Could you please give me the outout of your SNMP config file. I.e.:

cat /etc/snmp/snmp.conf

Also, it shouldn't matter, but perhaps you need to restart Apache to pick up the changes? (I note that I didn't state that you need to do that, so I suspect that you don't, but it can't hurt).

Luis Olavarrieta's picture

Jeremy, i just found this new error:

 

root@observium /opt/observium# php check-errors.php 

PHP Fatal error:  Allowed memory size of 536870912 bytes exhausted (tried to allocate 16384 bytes) in /opt/observium/includes/db/mysqli.inc.php on line 397

 

line 397 is   

 

      $rows = mysqli_fetch_all($result, MYSQLI_ASSOC);

 

Please advice!

Jeremy Davis's picture

It looks like when your server was loading all results from it's database, it used too much RAM. As per the message, it tried to allocate another ~16MB but that exceeded the allowed memory usage (of ~530MB).

My assumption is that it hit the limit allowed in the php.ini file. Note that there are 2 files, one for Apache and one for CLI. In this case you'll want to edit the CLI file (because when you hit the error you were running from the commandline) but it may pay to double check the Apache limit too.

In a v16.x appliance, the 2 files should be:

/etc/php/7.3/apache2/php.ini
/etc/php/7.3/cli/php.ini

As per the file path, the one you want to edit is the second one and look for the 'memory_limit' line and bump it up higher. It sounds like it's ~500MB currently, but needs to be higher. I would suggest adding an extra 64MB and see how that goes.

Alternatively, if you just wish to temporarily remove the PHP RAM limit while you run the command you're trying to run, you should be able do it ad hoc like this:

php -d memory_limit=-1 /opt/observium/check-errors.php